RF Pre-Amplifier Calibration
We provide calibration for RF Pre-Amplifiers. Our process follows the requirements of ANSI C63.5, resulting in data collection with a resolution of less than 500 kHz.
While this procedure may produce many data points, we will reduce the pre-amplifier gain factor data to a manageable list while maintaining an accuracy of 0.1 dB with respect to the full breath of data.
Our scope of accreditation is limited to 1 GHz, however we will increase our capability to 18 GHz in the very near future.
The table shown below describes our scope of accreditation for rf pre-amplifier calibration:
Parameter/Equipment | Range | Best Uncertainty (±) | Comments |
---|---|---|---|
RF Pre-Amplifiers | 1 MHz to 1 GHz | 0.38 dB | ANSI C63.5 Annex 1, ANSI C63.5 with HP8594E, 8494EM |